Dew point hygrometer, Chilled mirror, DewStar S-1

Shinyei Technology

Humidity / Moisture Sensing

Chilled Mirror Optical Dew Point Hygrometer DewStar S-1 series

The Dew Star S-1 chilled mirror system is a high performance chilled mirror SENSOR with Peltier thermoelectric mirror cooling.
It provides accurate and reliable dew point measurement over an extended range for long periods of time with it's new ACCU-STAR mirror maintenance feature.

Features

  • Accurate and reliable dew point measurement.

  • ACCU-STAR mirror maintenance feature.

  • Remote multifunction display monitor.

  • Simultaneously measure dew point, temperature, and pressure.

Specification

Model

DewStar S-1

Operation range

0 to 60℃ (Sensor)
0 to 35℃ (Monitor)
95%rh or less (no dewfall)

Measurement range of dew point

-40 to 50℃ 
* When a dew point temperature that is higher than the room temperature is measured, it is necessary to select the heater specification.

Operating pressure

0.5MPaG

Sampling flow rate 0.5 to 2.5 L/min.
Reproducibility ±0.05 ℃DP (at 25℃)
System accuracy ±0.1 ℃ DP(at 25℃ DP)
Measurement Parameter Dew/Frost point(℃), Temperature(℃), Pressure(kPa)
Operation Value Relative Humidity(%rh),Absolute Humidity(g/m3), Moisture Regain(PPMv) (PPMw)
Analog Output(Monitor) 4 to 20mA, 0 to 5VDC
Alerm Output(Sensor) Photo MOS relay
Digital Output RS232C
Sensor to Monitor Special Cable (Length 3m)
Connection 1/4" Compression Fitting PT
Weight Approx 0.5kg(Monitor)
Approx 4kg(Sensor *Depends on the specification.)
Power Supply AC90 to 240V (50/60Hz)
Consumed Power Approx 50W
Dimension(monitor unit)
(unit:mm)
monitor
Dimension(S-1)
(unit:mm)
S-1

Option

Temperature sensor S-1S-001

Sensor Pt100Ω 4-wire type
Measurement range -50 to 100℃
Accuracy ±0.2℃ (0℃)
Dimension φ3.2 x L250mm
Cable length

3m

S-1S-001

Air pump unit S-PU

Pumping sampling gas into Dew Star on measurement.Flow meter integrated.

S-PU

Order code

S-1 series (for normal humidity)*1

Order code Specification
Material of mirror Sensor coating Heater*2
Rhodium Platinum NO YES NO included
S-1S-0      
S-1S-4      
S-1S-6      
S-1S-8      
S-1S-C      
S-1S-E      

*1 Monitor display S-1M-0 is needed.

*2 Needed when dew point is highr than room temperature. Integrated with sensor and controlling unit. Must be ordered before shipped out of our factory. External temperature controller needed separately.

Monitor unit for S-1,S-2,S-3 common

Order code Specification
S-1M-0 SI unit

 

Option

Order code Specification
S-1S-001 Temperature sensor (Pt100Ω 4-wire type)
S-PU pump unit (100VAC 50/60Hz)

Calibration and Repair

After maintenance

SHINYEI provides calibration service traceble to National Metrology Institute of Japan(NMIJ) where standardizes humidity in Japan.

SHINYEI also operates all repairs of Dew Star at its own factory with fast lead time.

After maintenance

Download