Gas Sensor

For Air Purifier and IAQ monitor

SP3S-AQ2-01 For Air Purifier and IAQ monitor
Model SP3S-AQ2-01
Sensor Type Semiconductor
Detection Concentration Range N/A(depends on gases detected)
Accuracy N/A(depends on gases detected)
Response Time(T90) Within 1 minute
Detection Interval N/A (depends on user's design)
Power Supply VH=VC=5VDC±4%
Current Consumption (max.)60mA/ (ave.)42mA
Operating Temperature/
Humidity Range
0~40℃/under 95%RH (No condensation)
Storage Temperature/
Humidity Range
0~60℃/under 95%RH (No condensation)
Output Resistance
Alarm Output N/A
Size 7.6φ×13.4mm
Weight 0.6g

For Alcohol Breathalyzer

SB-30-04 For Alcohol Breathalyzer
Model SB-30-04
Sensor Type Semiconductor
Detection Concentration Range 20ppm~1,000ppm
Accuracy ±30% with calibration procedure
Response Time(T90) Within 1 minute
Detection Interval N/A (depends on user's design)
Power Supply VH=0.9VDC±4% (Able to use Pulse Operation) VC=under 5VDC
Current Consumption (max.)320mA/ (ave.)130mA
Operating Temperature/
Humidity Range
-10~50℃/under 90%RH (No condensation)
Storage Temperature/
Humidity Range
-20~60℃/under 95%RH (No condensation)
Output Resistance
Alarm Output N/A
Size 7.6φ×13.4mm
Weight 0.6g

For Breathalyzer of keto diet management

SB-33-00 For For Breathalyzer of keto diet management
Model SB-33-00
Sensor Type Semiconductor
Detection Concentration Range 1ppm~100ppm
Accuracy ±30%(After gas inspection)
Response Time(T90) Within 1 minute
Detection Interval N/A (depends on user's design)
Power Supply VH=0.9VDC±4% (Able to use Pulse Operation) VC=under 5VDC
Current Consumption (max.)320mA/ (ave.)130mA
Operating Temperature/
Humidity Range
0~40℃/under 90%RH (No condensation)
Storage Temperature/
Humidity Range
-10~70℃/under 90%RH (No condensation)
Output Ω in the clean air : 18kΩ~220kΩ
Alarm Output N/A
Size 7.6φ×13.4mm
Weight 0.6g

For Refrigerant R32 detection

FIS5000 series For Refrigerant R32 detection
Model FIS5000 series
Sensor Type Semiconductor
Detection Concentration Range 0~10,000ppm
Accuracy ±20%(at Alarm Concentration)
Response Time(T90) Within 30 seconds until it starts alarming 8,000ppm of R32
Detection Interval Less than 1 sec
Power Supply 5VDC±5%
Current Consumption (max.)80mA/ (ave.)40mA
Operating Temperature/
Humidity Range
-25~60℃/under 95%RH (No condensation)
Storage Temperature/
Humidity Range
-25~60℃/under 95%RH (No condensation)
Output UART/PWM
Alarm Output 5,000ppm for R32
Size 53.8 x 30 x max.22(Height)mm
Weight 12g

For CO2 concentration monitoring

IR-93S-04/100 For CO2 concentration monitoring
Model IR-93S-04/100
Sensor Type NDIR
Detection Concentration Range 400~5,000ppm
Accuracy ±50ppm+5% at Concentration Output
Response Time(T90) Within 1 minute
Detection Interval 2 sec
Power Supply 5VDC±10%
Current Consumption (max.)300mA/ (ave.)150mA
Operating Temperature/
Humidity Range
-20~70℃/under 90%RH (No condensation)
Storage Temperature/
Humidity Range
-20~85℃/under 90%RH (No condensation)
Output UART/PWM : 0~100%(400ppm~10,000ppm)
Alarm Output N/A
Size 64×23×10.7mm
Weight 13g

For Ozone detection

A1320301-SP61 series For Ozone detection
Model A1320301-SP61 series
Sensor Type Semiconductor
Detection Concentration Range 20~250ppb or 100ppb~1,000ppb
Accuracy ±30% at Alarm Concentration
Response Time(T90) Within 2 minutes
Detection Interval 1 sec
Power Supply 5VDC±4%
Current Consumption max.700mA
Operating Temperature/
Humidity Range
0~40℃/under 90%RH (No condensation)
Storage Temperature/
Humidity Range
-10~60℃/under 90%RH (No condensation)
Output Analog Output(0~1V or 0~5V)
Alarm Output About 80ppb or 700ppb
Size 51×37×22mm
Weight 15g

Comparison

  For Air Purifier and IAQ monitor For Alcohol Breathalyzer For Breathalyzer of keto diet management For Refrigerant R32 detection For CO2 concentration monitoring For Ozone detection
Model SP3S-AQ2-01 SB-30-04 SB-33-00 FIS5000 series IR-93S-04/100 A1320301-SP61 series
Sensor Type Semiconductor Semiconductor Semiconductor Semiconductor NDIR Semiconductor
Detection Concentration Range N/A (depends on gases detected) 20ppm~1,000ppm 1ppm~100ppm 0~10,000ppm 400~5,000ppm 20~250ppb or 100ppb~1,000ppb
Accuracy N/A(depends on gases detected) ±30% with calibration procedure ±30%(After gas inspection) ±20%(at Alarm Concentration) ±50ppm+5% at Concentration Output ±30% at Alarm Concentration
Response Time(T90) Within 1 minute Within 1 minute Within 1 minute Within 30 seconds until
it starts alarming 8,000ppm of R32
Within 1 minute Within 2 minutes
Detection Interval 1 sec N/A (depends on user's design) N/A (depends on user's design) Less than 1 sec 2 sec 1 sec
Power Supply VH=VC=5VDC±4% VH=0.9VDC±4%
(Able to use Pulse Operation)
VC=under 5VDC
VH=0.9VDC±4%
(Able to use Pulse Operation)
VC=under 5VDC
5VDC±5% 5VDC±10% 5VDC±4%
Current Consumption (max.)60mA/
(ave.)42mA
(max.)320mA/
(ave.)130mA
(max.)320mA/
(ave.)130mA
(max.)80mA/
(ave.)40mA
(max.)300mA/
(ave.)150mA
max.700mA
Operating Temperature/Humidity Range 0~40℃/under 95%RH (No condensation) -10~50℃/under 90%RH (No condensation) 0~40℃/under 90%RH (No condensation) -25~60℃/under 95%RH (No condensation) -20~70℃/under 90%RH (No condensation) 0~40℃/under 90%RH (No condensation)
Storage Temperature/Humidity Range 0~60℃/under 95%RH (No condensation) -20~60℃/under 95%RH (No condensation) -10~70℃/under 90%RH (No condensation) -25~60℃/under 95%RH (No condensation) -20~85℃/under 90%RH (No condensation) -10~60℃//under 90%RH (No condensation)
Output Resistance Resistance Ω in the clean air : 18kΩ~220kΩ UART/PWM UART/PWM : 0~100%(400ppm~10,000ppm) Analog Output(0~1V or 0~5V)
Alarm Output N/A N/A N/A 5,000ppm for R32 N/A About 80ppb or 700ppb
Size 7.6φ×13.4mm 7.6φ×13.4mm 7.6φ×13.4mm 53.8×30×max.22(Height)mm 64x23x10.7mm 51x37xmax.22mm